Main technical specifications
1. Nominal pressure: 1.6MPa
2. Working medium: water, gas
3. Working temperature: t≤80℃
4. High inlet pressure: 1.6MPa
5. Adjustable range of outlet pressure: 0.15MPa-0.50MPa (the pressure set at the factory is 0.3MPa)
6. Pipe thread complies with ISO228 standard
Working principle of spring-loaded pressure reducing valve Y12X/F:
Through the throttling of the opening and closing parts, the threaded pressure reducing valve Y12X/F causes pressure loss to force the inlet pressure to reduce a certain required value at the outlet. When the flow and pressure change, the purpose of using its own medium energy to control the outlet pressure is basically unchanged. .
Installation instructions for spring-loaded pressure reducing valve Y12X/F:
1. Before installing this valve, carefully check whether the usage is consistent with the label.
2. The threaded pressure reducing valve can be installed horizontally or vertically, and the arrow shown on the valve body must be consistent with the flow direction of the medium.
3. This valve is only used for decompression in the pipeline, not for cut-off. The medium used must be filtered by a filter.
Spring pressure reducing valve model:
Cast steel: Y12X-16C, Y12X-25C, Y12X-40C, Y12X-64C
Stainless steel: Y12F-16P, Y12F-25P, Y12F-40P, Y12F-64P
Dimensions of pressure reducing valve Y12F/X:
model |
Size (mm) |
||||||||||||
Y12F-16P |
DN |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
L |
160 |
160 |
180 |
200 |
220 |
250 |
260 |
310 |
350 |
400 |
500 |
550 |
|
H1 |
170 |
170 |
188 |
192 |
270 |
270 |
310 |
403 |
448 |
570 |
590 |
640 |
|
H2 |
75 |
75 |
77 |
82 |
98 |
98 |
138 |
152 |
170 |
222 |
242 |
262 |